GB – Instructions for Series 9000 Masks
Important Information for Users
This manual is only valid in conjunction with the instruction manual for Moldex Series
7000/9000 gas and particulate filters. Failure to comply with these instructions on
how to use the product and failure to wear the respiratory protection in the polluted
area may negatively impact on the health of the user and lead to permanent damage
and life-threatening injuries.
• This breathing apparatus does not supply oxygen (02) • Only use the product in ad
-
equately ventilated areas,(19.5 Vol.-% oxygen) • The mask and filters must be selected
in accordance with the pollutant type and concentration (see Table 2). • In the case
of gases with insufficient warning properties, filters may only be used if special usage
policies are specified for this purpose. • If the conditions are uncertain or changeable,
self-contained breathing apparatus must be worn. • You must exit the working area
and replace the respirator mask immediately if: – the mask is damaged, – you expe
-
rience difficulty in breathing, – you experience dizziness or fatigue. – you can taste
or smell hazardous substances or if you experience irritation • Read the instruction
manual before using the mask. • The product does not contain any metallic parts that
could cause ignition in potentially explosive atmospheres. • If you have any questions
about how to use the product, please contact Moldex-Metric. • You must also observe
the relevant rules and regulations when using respiratory equipment. • Under certain
circumstances, persons with beards, long sideburns or other anomalies in the area
around the sealing lines may be unable to achieve a proper sealing fit. Spectacle
frames that extend under the sealing line will impede a proper sealing fit. • The masks
must not be modified in any way. • Users of the masks and filters must be familiar with
how to handle them correctly. • When not in use, the mask and filter must be stored in
an uncontaminated environment.
Caution: Do not use filter equipment in unventilated containers and confined spaces.
Preparations Before Using the Full-mask
The full-mask must always be checked before use. Do not use a damaged or defective
mask. Seek the immediate assistance of a supervisor.
You must check • The mask and the filters for fractures, deformations, cracks and
contamination. • Whether the head strap is torn, nicked or damaged in any other way
and whether it provides sufficient elasticity. • The inhalation and exhalation valves
as well as the sealing rings on the filter connections for contamination, deformation,
fractures and cracks. Make sure that the valves and sealing rings are fitted correctly. •
The use-by-date of the filter and their correct fitting in accordance with the instruction
manual for gas and particulate filters. Fitting/removing the full-mask (Figures 1, 2, 3
and 4) Open the straps fully at the 4 adjustment points and hold the head strap with
one hand at the bracing with the Moldex lettering. Place the opening of the head strap
at the back of the neck and pull the mask down over your face from above. At this point,
make sure that no hairs are trapped between the sealing lip and your face. Position
the mask on your face and use one hand to press the mask firmly against your mouth
and chin. Now use your other hand to pull the neck strap tight on one side and then
repeat the procedure on the other side. To ensure the best possible seal between mask
and face, you should always tighten the neck straps first. The head strap must lie flat
on your head. To ensure that the mask fits comfortably, adjust the head and neck strap
equally. Before entering your working area, check that the mask creates a seal around
the face. To remove the mask, first loosen the clips on the neck strap by pulling the mask
away from your face. Using suction to check the face seal (Figure 5) Place the palm
of your hand over the opening on the filter cover to seal it and breathe in slowly. If the
facepiece contracts slightly, the mask is correctly seated. If you notice an inflow of air,
adjust the position of the mask on your face or adjust the tension of the straps. Repeat
this check until a seal is achieved. Using excess pressure to check the face seal (Figure
6) For full-masks equipped with an EN 148-1 connection, check the face seal before
fitting the filter to the facepiece. Place the palm of your hand over the exhalation valve
and breathe out slowly. If no air escapes between the facepiece and your face, a prop
-
er sealing fit is achieved. If you notice air escaping, adjust the position of the mask on
your face or adjust the tension of the straps. Repeat this check until a seal is achieved.
Under no circumstances should you enter a hazardous area if you are unable to
achieve a proper sealing fit. Seek the assistance of a supervisor.
Maintaining the Full-mask
The maintenance intervals as set out in the national regulations must be adhered to.
The date of manufacture is shown on the inside of the face seal in the chin area.
Cleaning/Disinfection We recommend cleaning the mask after each use. If not in use,
clean the mask after 6 months at the latest. Remove the filter; clean the facepiece
with warm water (max. 50°C). If necessary, use a neutral cleaning agent and an
alcohol-based disinfectant. To clean the valve membrane, remove it from the holder.
To clean the inner mask, unfasten it from the two stop points. To refit it, use the guide
rails on the lower part of the lens and the two stop points. To dismantle the filter, refer
to the instruction manual for gas and particulate filters. After having cleaned or disin
-
fected the mask, the face seal needs to be checked by means of suitable leak testing
equipment. Before cleaning pull the protective film away from the lens Dry the mask
thoroughly before putting on a new protective film and before storing it. Storage Keep
the 9000 mask sealed in a dry, uncontaminated environment. Protect against sunlight
and sources of heat (see the "Storage" icons). The name of the wearer and a record
of the filter changes can be noted on the packaging. Caution: At low temperatures,
moisture can cause the valves to freeze up. The date of manufacture is engraved on
the inside of the mask. Calendar clocks see page 39. Exhalation Valve (Spare Part
No. 9974 [b]) Fold down the cover of the exhalation valve and check the exhalation
valve and valve seat for contamination, deformation, fractures or cracks. Replace the
valve membrane when necessary, or every 4 years at the latest. Please note date of
replacement. Inhalation Valve (Spare Part No. 9974 [a]) Check the inhalation valve
on the inner mask and on the inside of the filter connection for contamination, defor
-

Vestelge oma Moldex Series 9000 EasyLock juhendiga AI abil

Saage oma Moldex Series 9000 EasyLock juhendist kohe AI-vastuseid

Küsige Moldex Series 9000 EasyLock kohta ükskõik mida. Vastused pärinevad sellest juhendist koos lehekülgedega, millele need tuginevad.

Series 9000 EasyLock Hooldusgraafik

Tuleta mulle meelde, kui hooldus on vajalik
Iga 6 kuu tagant
Puhastage kasutamata maski

Kui mask ei ole kasutusel, puhastage seda vähemalt iga 6 kuu tagant, et tagada hügieen ja toimivus.

Kuva juhendis (lehekülg 5)
Iga 4 aasta tagant
Vahetage väljahingamisklapi membraan

Vahetage väljahingamisklapi membraan vajadusel või hiljemalt iga 4 aasta tagant. Salvestage vahetamise kuupäev.

Kuva juhendis (lehekülg 5)
Pärast igat kasutuskorda
Puhastage ja desinfitseerige maski

Eemaldage filtrid ja puhastage näomask sooja veega (maksimaalselt 50°C). Vajadusel kasutage neutraalset puhastusvahendit/alkoholipõhist desinfitseerimisvahendit. Kontrollige tihendust pärast puhastamist.

Kuva juhendis (lehekülg 5)
Enne igat kasutuskorda
Kontrollige maski ja klappe

Kontrollige enne kandmist maski, filtreid, pearihma, sisse- ja väljahingamisklappe ning tihendusrõngaid kahjustuste, mustuse või moonutuste suhtes.

Kuva juhendis (lehekülg 5)

Tasuta hoolduse meeldetuletused

Lähtudes ostukuupäevast. Alati tasuta, loobuge tellimusest igal ajal.

Esitades nõustute privaatsuspoliitikaga. Loobuge tellimusest ühe klõpsuga mis tahes e-kirjas.
M: qwen/qwen3.8-flash

Poser une Question

0/1000

Recommandez-vous Series 9000 EasyLock ?

Oui Non

Korduma kippuvad Küsimused

A

Ei, see hingamisaparaat ei tooda hapnikku. Seda kasutatakse ainult piirkondades, kus on piisav ventilatsioon ja hapniku maht on vähemalt 19,5%.

Cette réponse est-elle utile ?

A

Soovitatav on puhastada maski pärast iga kasutust. Kui seda ei kasutata, tuleb seda puhastada vähemalt iga kuue kuu tagant, et vältida saastumise kogunemist.

Cette réponse est-elle utile ?

A

Prilliraamid, mis ulatuvad suletusjoone alla, takistavad korralikku suletust. Võite kasutada valikulist prillide hoidjat, kuid veenduge, et raam ei katkesta suletust.

Cette réponse est-elle utile ?

A

Peate kohe lahkuma töökohalt ja asendama hingamismaski. Ohtlike ainete tundmine või maitsemine näitab suletuse rikkumist või filtrite küllastumist.

Cette réponse est-elle utile ?

A

Jah, toode ei sisalda metalliosi, mis võiksid põhjustada süttimist potentsiaalselt plahvatusohtlikes atmosfäärides, muutes selle sellistes keskkondades ohutuks.

Cette réponse est-elle utile ?

A

Teostage suletuskontroll, asetades käe filtri avale ja inhaleerides aeglaselt. Kui mask kokku tõmbub pisut, on suletus õige. Alternatiivselt katkestage väljahingamise ventilaator ja exhaleerige kergelt, et kontrollida lekete suhtes.

Cette réponse est-elle utile ?

M: QW-35-FL

Avantages et Inconvénients

Avantages

  • Vastab EN 136:1998 CL2 standardile kõrgetasemelise hingamiskaitse jaoks
  • EasyLock peanööri süsteem võimaldab kiiret ja täpset reguleerimist
  • Ühilduv lai valik P1, P2, P3 osakestefiltri ja gaasi klassi filtreid
  • Metalliosade puudumine vähendab süttimisohtu potentsiaalselt plahvatusohtlikes atmosfäärides
  • Selge vaate polükarbonaat lääts valikulise prillihoidja integreerimisega
VS

Inconvénients

  • Nõuab rangelt kinni pidamist hooldusskeemidest, et tagada pikaealisus
  • Särad või näokarvad võivad takistada korraliku suletuse saavutamist
  • Prillide käed, mis ulatuvad suletusjoone alla, võivad ohustada suletust
  • Ventilaatorid võivad jääda külma temperatuuri ja niiskuse esinemisel
  • Filtri valik peab vastama spetsiifilistele saasteainete tüüpidele ja kontsentratsioonidele täpselt
M: QW-35-FL

Toode Spetsifikatsioon

Omistukset

Venttiili, kasvosuoja, nelipisteinen turvaliina, säädettävä, vaihdettava suodatin

M: QW-35-FL

Produit Description

Kaitse oma kopsude Moldex Series 9000 EasyLock hingamismaskiga

Moldex Series 9000 EasyLock hingamismaski täismask on tipptasemel isikukaitsevahend, mis on loodud nõudlikuks tööstuskeskkonnaks. See tugev täismask pakub põhjalikku kaitset laia hulga ohtlike ainete eest, sealhulgas mürgiste gaaside, aurude ja osakeste vastu. See on kavandatud vastama rangele EN 136:1998 CL2 standardile, tagades kasutajate kaitsmise eluohtlike saasteainete eest ning säilitades mugavuse pikaajalisel kandmisel.

Üks selle hingamismaski silmapaistvaimaid omadusi on tema innovatiivne EasyLock süsteem, mis lihtsustab maski panemise ja võtmise protsessi. Peanööridel on neli reguleerimispunkti, võimaldades kohandatud sobitust erinevatele näo kuju tüüpidele. Õige sobitus on kriitiline; mask peab tekitama õhuhermeetilise suletuse ümber suu ja lõua ilma juukseid või prilliraamide raame tabamata. Kasutajatel soovitatakse läbi viia nii negatiivse kui ka positiivse rõhu kontroll enne sisenemist saastunud piirkonda, et kinnitada suletuse terviklikkust.

Hooldus ja hügieen on eriti olulised hingamiskaitse vahendite kasutamisel. Käsitöö soovitab puhastada näomaski pärast iga kasutust sooja veega, mis ei ületa 50 kraadi Celsiusest. Sügavamaks desinfitseerimiseks saab kasutada neutraalseid puhastusaineid ja alkohoolseid desinfitseerijaid. On kriitiline eemaldada filter, puhastada sisemisi maski komponente ja kontrollida ventiile prügi või kahjustuste eest enne hoiustamist. Maski tuleb alati hoida kuivas, saastumata keskkonnas, eemal otsest päikesevalgust ja kuumusallikatest, et vältida materjali halvenemist.

Mitmekülgsus on veel üks Series 9000 peamine aspekt. See toetab erinevaid filtreid, alates P1 osakestefiltritest, mis pakuvad 4 korda rohkem töökeskkonna eksponeerimispiiri (WEL), kuni Class 2 gaasifiltriteni, mis pakuvad kuni 20 korda WEL-i või 5000 ppm. Spetsiifilised mudelid nagu 9004, 9005 ja 9006 kasutavad EN 148-1 ühendust standarditud filtri kinnitamiseks. Olgu teil siis keemiatöötlemises, põllumajanduses või hädaolukorra reageerimises, see hingamismask pakub usaldusväärsust, mida on vaja tervise kaitsmiseks.

Tähtsad hooldusjuhised

Asendage väljahingamise ventiili membraan vähemalt iga nelja aasta järel. Veenduge, et ninatupp ja peanöörid kontrollitakse regulaarselt kulumise suhtes. Kui maskil on pragusid, deformatsiooni või saastumist, visake see kohe välja. Ära kunagi muuda maski struktuuri, kuna see tühistab garantii ja ohustab turvalisust.